Product Description

The galvo motor is one of the most core components of scanners, we has introduced the most advanced international photoelectric sensor control mode, and carried on the comprehensive optimization design from the scanner mechanical aspects, greatly reduced the scanner size, improved the marking speed and precision, the products performance and stability has reached the leading level at home and abroad.

Model: JS1105
Product Name:Galvo Scanner Motor for Medical Devices
Material of outer holder: Aluminum Alloy
Color Of Outer holder: Silver
Motor weight: 13g
Function & Application: Beauty machine, Medical beauty galvo scanner
Product Advantages:This galvo motor has the characteristics of fast response speed, high precision, good stability, especially suitable for the high precision instruments for medical and beauty industry.
JS1105 Galvo Motor Size Drawing

SG1105 High Speed Galvanometer Scanner motors are introduced from America, has the advantages of small size, high speed & high precision, good stability, etc.
This model has the good running stability, high positioning accuracy, fast marking speed, strong anti-interference ability, the overall performance of SG1105 has reached the international leading level in this field. The advantages are as following:
■ Adopted with high-performance scanning motor which imported from the America and the international advanced photoelectric sensing technology.
■ Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning.
■ Drives with advanced detection ability of position and speed, greatly improved the dynamic response performance and scanning speed of the whole system.
■ Design of overload, over-current and reverse connect protection, makes the system running more reliable.
■ The whole system adopted the Optimization Designing of electromagnetic compatibility, with high signal-to-noise ratio and strong anti-interference ability.
■ Scanner size is smaller, with 7mm beam input aperture, which can meet the industrial demands of higher speed, higher precision and more compact systems.
■ With only 700g total weight, the scanner can be integrated into different application systems easily. The housing is very strong and dustproof. Thus it can be used in the extremely bad environment.
JS1105 Galvo Motor Parameter Details:
Working Temperature | 0-45°C |
Linearity | 99.9% |
Setting Time | ≤0.35ms |
Scale Drift | 40PPM/°C |
Zero Drift | <15μRad./°C |
Long-term Drift Over 8 Hours | <0.5mRad |
RMS Current | 2.0A |
Peak Current | 10A(Max) |
Maximum Scan Angle | ±15° |
Storage Temperature | -10 to +60°C |
Resolution | 12μrad |
Repeatability | 8μrad |
Input Aperture | 5.0-7.0mm |
Beam Displacement | 10.7mm |
Motor Weight | 13g |
Frequency | ≤1000Hz |
Input Voltage MAX.RMS | ±15VDC |
Interface Signals Analog | ±5V |
Fault signal output(TTL level) | H is for galvanometer working normally, L for galvanometer failure |
Analog Signal Input Resistance | 200KΩ±1% |
Position Signal Input Resistance | 1KΩ±1% |
Position Signal Input Scale Factor | 0.33V/° |
Position Signal Output Scale Factor | 0.33V/° |
Working Temperature | 0-45℃ |
Dimension(L×W×H) | 75×50×28mm |
Self-checking and FAQ
Before starting up the whole system, please check carefully to confirm whether there is any problems, such as: plug virtual connection or without connection, two mirrors touched with each other, drive board signal input errors, etc. Only after finishing all checking, then you can turn on the power supply.
Fault Phenomenon | Reasons | Solutions |
System has no any reactions | No power supply or the circuit did not connect well. | Check if the power supply is connected well |
Red light keeps on with "KaBa" sound | Position limitation protection | Check if over input signal amplitude. If the signal is normal, please contact us. |
Scan motor swings lightly after turning on | Too much interference or input signal circuit did not connect very well | Check the interference sources and the input signal circuit |
Motor squeals after turning on, the drive board and motor overheat | Driver board and motors did not connect well/The mirrors or clips become loosen. | Check the wiring/ the mirrors and clips. |
Mirror reflection power is weak | Light path is not aligned well | Align the light path of the marking machine; If the light path is normal, please contact us. |
Marking graphics becomes one straight line | One motor cannot move normally | Checking the wiring connection between the motors, drive boards and control board |
Waves exist in the marking line | Grounding problems/ Surrounded by strong interference sources/The Anti-interference ability of marking control board is poor | Check if the ground connection is well/Check if there is a strong interference source surrounded/ Check the position control signal of marking control board |
Marking square becomes rhombus or one side not straight | Abnormal signal output from D/A board. | Replace D/A board, if not solved, please contact us. |
As the leading galvanometer scanner manufacturer in the world, Sino-Galvo Tech. launched JS1105 galvo canner,the lasted medical and beauty CO2 handheld galvanometer scanner system. It uses a combination of modular design, and achieves the functions of interface display, parameter settings and scanning control for whole system. It employs advanced moving magnet galvanometers and precision servo drivers for high performance.
Hot Tags: oct galvanometer scan motor, China, suppliers, manufacturers, customized, low price, application of