Product Description

SM1105 is the latest R&D of high performance medical beauty galvanometer scanner. The scanner hand piece designing was adopted the unique vertically into the light structure. It has the characteristic of small volume, light weight, high speed, easy operate etc. A full range of security protection function, custom software development which makes the stability and reliability of the scanner reached the world leading level. It also has independent intellectual property rights.
Motor Specification
Working Temperature: 0℃-45℃
Linearity: 99.9%
Setting Time: ≤0.35ms
Scale Drift: <40PPM/℃
Zero Drift: <15μRad./℃
Long-term Drift Over 8 Hours: <0.5mRad
RMS Current: 2.0A
Peak Current: 10A
Maximum Scan Angle: ±15°
Storage Temperature: -10 to +60℃
Resolution: 12μrad
Repeatability: 8μrad
Input Aperture: 5.0-7.0mm
Beam Displacement: 10.7mm
Weight: 13g
Frequency: ≤1000Hz
Servo Drive Board Specification
Input Voltage: ±15VDC
Interface Signals Analog: ±15V
Analog Signal Input Resistance: 200KΩ±1%
Position Signal Input Resistance: 1KΩ±1%
Position Signal Input Scale Factor: 0.33V/°
Position Signal Output Scale Factor: 0.33V/°
Working Temperature: 0 degrees-45 degrees
Dimension (length*width*height): 75x58x33mm
The Characteristics of SM1105 Scanner:
1. The scanner hand piece designing was adopted the unique vertically into the light structure, only weights 300g, the operation is flexible and convenient.
2. Adopted the world’s smallest scanning motors, the photoelectric sensors is imported from America, only weights 13g, the marking speed is two times faster than common scanners, the setting time reaches 0.35ms.
3. The Driving system adopted the control method of Germany glavo scanners, two motors are centralized controlled by only one drive board, the performance is stable, reliable and high accuracy. All precision electronic components are imported from aboard.
4. With powerful software function, convenient parameter settings, a variety of scanning shapes and scanning mode for options, the scanning shapes can be two-way adjusted.
Control Board Wiring Diagram

Potentiometer Adjustment
W1: Adjusting the graphics X axis proportion
W2: Adjusting the graphics X axis displacement
W3: Adjusting the graphics Y axis displacement
W4: Adjusting the graphics Y axis proportion
W5: Laser power maximum value adjustment (It needs to tune to be 5V when setting the maximum laser power on the software).
If you have any questions, please contact our Technical s Department:
consulting hot-line: 400-055-8805
Hot Tags: medical galvo scanner for gynecological treatment, China, suppliers, manufacturers, customized, low price, application of